Filters and filter elements

BLP-0931

Liquid Vapor Filtration Unit

Price: on request
BLP-0931. Liquid Vapor Filtration Unit

The purification unit is designed to filter liquid vapors generated in the working compartment of equipment for testing fuel equipment.

Principle of operation:
Polluted air is sucked through the intake pipe into the lower chamber and, under the influence of centrifugal forces, enters further into the separation chamber, where, circulating through the labyrinth system, the main purification of air from oil vapors and emulsions takes place. Further, the air passes into the upper chamber and, passing through another filter element, returns to the working room. The collected liquid flows back into the working compartment through the drain tube.

No. Name Quantity
1 Lid 1 pcs
2 Body 1 pc
3 Stand 1 pc
4 Drainage tube 1 pc
5 Intake pipe 1 pc.
6 Mounting points according to size □177 mm 4 pcs

Power supply: standard single-phase 230 V, 50 Hz or three-phase 230/400 V, 50 Hz.
Electric motor power 0.224 kW – 0.274 kW.
Overall dimensions (length x width x height), mm 412 x 412 x 388.
Weight – 25 kg.
The number of revolutions of the fan on the electric motor: 2500 rpm-2756 rpm.
Maximum productivity at (P=100 Ra) 1000 m3h – 1325 m3/h
Maximum pressure 714 Pa.
The maximum temperature of the filtered mist (air) is 50°.

Recently viewed

  • Clamp-adapter #0124 for pump injectors Volvo FH12, Iveco (Bosch)

    on request
  • Clamp adapter for testing unit injectors CAT 3920206

    on request
  • Set with CIG for measuring the height of washers and springs of CRI1/CRI2 injectors

    on request
  • Kit for extracting and installing the sealing ring and installing the injector valve

    on request